Customer Service: +61 3 8470 7300
  • Homepage
  •  

    Sentryline – M® Wire Rope Terminal End

Sentryline – M® Wire Rope Terminal End

Send to printer
Product Image

View gallery images

DESCRIPTION

End of Line

The Sentryline – M® Wire Rope Terminal End is used to anchor the high tensioned four-cable Sentryline – M® Wire Rope Barrier and features a unique assembly of trigger post, deflection post and connecting rail for added safety during end-on motor vehicle impact collisions.

It has been designed and tested to meet the evaluation criteria of MASH (2016) TL-3 and is used to anchor the Sentryline - M® Wire Rope Barrier which is a MASH (2016) TL-3 and TL-4 product.

FEATURES

End of Line
  • Tested to MASH (2016) TL-3 by Holmes Solutions 
  • Approved by Austroads Safety Barrier Assessment Panel (ASBAP)
  • Quick to repair after a collision
  • A non releasing terminal end
  • Does not include any plastic parts - which could be damaged by bush fires
  • Terminal end supported by either mass concrete block or drilled reinforced concrete piles
  • Designed in New Zealand - Patent pending (WO 2020/128929)

OTHER RELATED PRODUCTS

End of Line

Sentryline II Wire Rope Safety Barrier System

Sentryline II WRBS TL3 Tested Terminal End

Sentryline Terminal End III - Non release terminal

Sentryline – M® Wire Rope Barrier

STANDARDS AND APPROVALS

End of Line
  • AS/NZS 3845 – Part 1 Product
  • MASH (2016) TL-3 tested by Holmes Solutions
  • Approved by Austroads Safety Barrier Assessment Panel (ASBAP)

SPECIFICATIONS

End of Line
  • Cable – 19mm 3 x 7 strand, pre-stretched by 35%
  • Transition Line Post footing piles are 300mm diameter x 750mm (0.05m3)
  • Length of Need is met at Transition Line Post 5 
  • Deflection Post and Transition Line Post 1 are spaced at 1.5m (LoN to the Deflection Post)
  • Transition Line Posts 2 - 5 are spaced at 3m (straight)
  • Transition Line Post 5 has no Half Ties installed
  • Tensioned to 25kN at 20°C (Tension may vary depending on air temperature at time of installation, see chart in Product and Installation Manual)
  • Max flare, 300mm over 10m of the terminal end (offset from tangent)
  • All components are hot dip galvanised (posts are all hot dip galvanised with an optional powder coated finish)
  • Concrete is 25MPa
DocLaunch Page Launch